Engineering tool

Plate order thickness calculator

Enter the thickness your drawing needs, the plate size and the quantity. The calculator gives the nominal thickness to order under IACS UR W13, the thinnest and thickest a plate may be under the rule, and the weight at each limit.

01

Settings

The value I enter is
02

How this was worked out

UR W13.3.2: the minus tolerance is 0.3 mm for hull steel whatever the thickness. Nominal = required + 0.3 mm, rounded up to the ordering step.

UR W13.4.2: the average of the measurements must not be below the nominal thickness.

03

Plates

01
Thickness (mm)mm
Width (mm)mm
Length (mm)mm
Pieces#
12.5mm nominal
Smallest nominal that works12.3 mmThinnest allowed at any point12.2 mmAverage must be at least12.5 mmWeight per piece1.177 tExtra weight versus the drawing value0.471 t
02
Thickness (mm)mm
Width (mm)mm
Length (mm)mm
Pieces#
20.5mm nominal
Smallest nominal that works20.3 mmThinnest allowed at any point20.2 mmAverage must be at least20.5 mmWeight per piece4.828 tExtra weight versus the drawing value0.471 t
All plates
Total weight at nominal31.086 t
Total weight if all at the lower limit30.521 t

Your list is saved in your browser only and is never uploaded. Use Clear all to delete it.

What this calculator covers

IACS UR W13 (Rev.6, 2018) for plates and wide flats of 600 mm width and above: the 0.3 mm minus tolerance on hull structural steel (UR W11) and high strength steel for welded structures (UR W16), Table 1 minus tolerances for machinery structure steel, and the rule that the average thickness must not be below the nominal thickness.

What it does not cover

Plus tolerances: UR W13 leaves them to a recognised standard or your contract, so you enter the value yourself. It also does not cover plates ordered to Class C of ISO 7452 (which replaces W13.3), width, length and flatness tolerances, or the mill's own rolling limits. Check the rolled thicknesses and steps with the mill.

Source

Minus tolerance, average thickness and the machinery steel table were taken from IACS Unified Requirement W13 (Rev.6, 2018) and checked against the published text. Original: IACS UR W13 (PDF)

This arithmetic aid does not constitute an approval. The thickness on your class-approved drawing and the contract with the mill govern. For plates ready to ship, contact us. Request a quote

Common questions
Why does the order thickness come out 0.3 mm above my drawing?
UR W13 allows a hull steel plate to be 0.3 mm thinner than its nominal thickness at any measured point. A plate ordered at exactly the drawing thickness can therefore be 0.3 mm under it. If your drawing thickness is a minimum at every point, the nominal has to be higher. If your class rules or drawing already include the tolerance, choose the nominal option instead.
Does the average thickness rule give me extra steel?
UR W13 requires the average of the measurements not to be below the nominal thickness. A correctly rolled plate is therefore, on average, at or above nominal, and individual points may sit between the lower limit and the upper limit. Whether the contract is priced on nominal or on actual weight changes your cost, so settle that with the mill.
Why is there no built-in plus tolerance?
UR W13 says plus tolerances follow a recognised national or international standard or the purchaser's requirement, and it gives no numbers. Those standards have several classes and are not freely published, so the calculator takes the plus tolerance from you. Leave it empty to see only the lower limit.